{"id":2180,"date":"2025-12-17T02:23:58","date_gmt":"2025-12-17T02:23:58","guid":{"rendered":"https:\/\/totalquartzworks.com\/?page_id=2180"},"modified":"2026-01-05T02:58:14","modified_gmt":"2026-01-05T02:58:14","slug":"gas-chromatography-columns-definition-%c2%b7-selection-%c2%b7-method-development","status":"publish","type":"page","link":"https:\/\/quartz.10smt.com\/es\/gas-chromatography-columns-definition-%c2%b7-selection-%c2%b7-method-development\/","title":{"rendered":"Columnas de cromatograf\u00eda de gases (Definici\u00f3n - Selecci\u00f3n - Desarrollo de m\u00e9todos)"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"2180\" class=\"elementor elementor-2180\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea7c036 e-con-full e-flex e-con e-parent\" data-id=\"ea7c036\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-476dc7f e-con-full e-flex e-con e-child\" data-id=\"476dc7f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e5ae9c9 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"e5ae9c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed2ce49 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"ed2ce49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb97dde elementor-widget__width-initial elementor-widget elementor-widget-heading\" data-id=\"fb97dde\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Columnas de cromatograf\u00eda de gases (Definici\u00f3n - Selecci\u00f3n - Desarrollo de m\u00e9todos)<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b91040 elementor-widget elementor-widget-text-editor\" data-id=\"7b91040\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"118\" data-end=\"316\">Este art\u00edculo se centra en las columnas de cromatograf\u00eda de gases, partiendo de los conceptos m\u00e1s b\u00e1sicos y explicando qu\u00e9 hacen, por qu\u00e9 son importantes y c\u00f3mo elegir la columna adecuada para un trabajo anal\u00edtico real.<\/p>\n<p data-start=\"323\" data-end=\"534\" data-is-last-node=\"\">Si tiene dudas sobre el tipo de columna, el di\u00e1metro interior, la longitud o el grosor de la pel\u00edcula en el an\u00e1lisis por CG, o si el rendimiento de su separaci\u00f3n es insatisfactorio, esta p\u00e1gina est\u00e1 pensada para aclarar esas dudas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff0cb1c e-con-full e-flex e-con e-parent\" data-id=\"ff0cb1c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-68c7f78 e-con-full e-flex e-con e-child\" data-id=\"68c7f78\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eea25d0 elementor-widget elementor-widget-table-of-contents\" data-id=\"eea25d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"table-of-contents.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2d18fb7 e-con-full e-flex e-con e-child\" data-id=\"2d18fb7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c86049 elementor-widget elementor-widget-heading\" data-id=\"3c86049\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Qu\u00e9 es una columna de cromatograf\u00eda de gases<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-108c2af elementor-widget elementor-widget-heading\" data-id=\"108c2af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Definici\u00f3n b\u00e1sica: \u00bfQu\u00e9 es una columna de cromatograf\u00eda de gases?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b83bb72 elementor-widget elementor-widget-text-editor\" data-id=\"b83bb72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>En t\u00e9rminos sencillos, una columna de cromatograf\u00eda de gases es el \"coraz\u00f3n\" y el \"motor de separaci\u00f3n\" de un cromat\u00f3grafo de gases. Funciona como una pista de marat\u00f3n para las mol\u00e9culas.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p><strong>Funci\u00f3n principal:<\/strong> Separa las distintas sustancias qu\u00edmicas mezcladas en la muestra.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p><strong>Principio de funcionamiento:<\/strong> Cuando la muestra vaporizada es empujada por un gas portador inerte (como hidr\u00f3geno, helio o nitr\u00f3geno) a trav\u00e9s de una larga columna de cromatograf\u00eda, los distintos componentes interact\u00faan con la fase estacionaria recubierta en la pared interior de la columna con distinta fuerza, lo que hace que \"corran\" por la columna a distintas velocidades.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:list --><\/p>\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Mol\u00e9culas con interacciones d\u00e9biles: corren m\u00e1s r\u00e1pido y llegan antes al detector.<\/li>\n<!-- \/wp:list-item --><!-- wp:list-item -->\n<li>Mol\u00e9culas con fuertes interacciones: corren m\u00e1s despacio y llegan m\u00e1s tarde al detector.<\/li>\n<!-- \/wp:list-item --><\/ul>\n<p><!-- \/wp:list --><!-- wp:paragraph --><\/p>\n<p><strong>Resultado final:<\/strong> Las mol\u00e9culas originalmente mezcladas eluyen de la columna una a una por orden de velocidad, y el detector las registra como picos separados en el cromatograma, lo que permite realizar an\u00e1lisis cualitativos y cuantitativos.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d443808 elementor-widget elementor-widget-heading\" data-id=\"d443808\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Componentes clave de una columna de cromatograf\u00eda de gases<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-696e829 elementor-widget elementor-widget-text-editor\" data-id=\"696e829\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Seg\u00fan las dimensiones de la columna y el formato de la fase estacionaria, las columnas de GC se clasifican principalmente en dos tipos:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b611c9 elementor-widget elementor-widget-heading\" data-id=\"9b611c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">1. Columnas capilares (la corriente dominante hoy en d\u00eda)<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-875f8bf elementor-widget elementor-widget-text-editor\" data-id=\"875f8bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><!-- wp:list --><\/p><ul class=\"wp-block-list\"><!-- wp:list-item --><li><strong>Estructura:<\/strong> Un capilar de s\u00edlice fundida muy largo (normalmente de 10-60 metros de longitud y 0,1-0,53 mm de di\u00e1metro interior) con un recubrimiento de fase estacionaria fino (normalmente de 0,1-5,0 \u00b5m).<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Ventajas:<\/strong><!-- wp:list --><ul class=\"wp-block-list\"><!-- wp:list-item --><li>Eficacia de separaci\u00f3n extremadamente alta: los platos te\u00f3ricos pueden alcanzar varios miles por metro, capaces de separar mezclas muy complejas.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li>An\u00e1lisis r\u00e1pido gracias a su baja resistencia<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li>Requiere cantidades de muestra muy peque\u00f1as<\/li><!-- \/wp:list-item --><\/ul><!-- \/wp:list --><\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Aplicaciones:<\/strong> Adecuado para casi todas las muestras anal\u00edticas complejas: petr\u00f3leo, contaminantes medioambientales, fragancias, productos farmac\u00e9uticos, etc.<\/li><!-- \/wp:list-item --><\/ul><p><!-- \/wp:list --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d82308c elementor-widget elementor-widget-image\" data-id=\"d82308c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"606\" height=\"565\" src=\"https:\/\/quartz.10smt.com\/wp-content\/uploads\/2025\/11\/Capillary-fused-silica-column-\u2014-medium-polarity-GC-column.png\" class=\"attachment-medium_large size-medium_large wp-image-1339\" alt=\"Columna capilar de s\u00edlice fundida - columna GC de polaridad media\" srcset=\"https:\/\/quartz.10smt.com\/wp-content\/uploads\/2025\/11\/Capillary-fused-silica-column-\u2014-medium-polarity-GC-column.png 606w, https:\/\/quartz.10smt.com\/wp-content\/uploads\/2025\/11\/Capillary-fused-silica-column-\u2014-medium-polarity-GC-column-300x280.png 300w, https:\/\/quartz.10smt.com\/wp-content\/uploads\/2025\/11\/Capillary-fused-silica-column-\u2014-medium-polarity-GC-column-13x12.png 13w\" sizes=\"(max-width: 606px) 100vw, 606px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Columna capilar de s\u00edlice fundida - columna GC de polaridad media<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e3a84d elementor-widget elementor-widget-heading\" data-id=\"4e3a84d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">2. Columnas empaquetadas (tipo tradicional, ahora menos utilizado)<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61343ce elementor-widget elementor-widget-text-editor\" data-id=\"61343ce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><!-- wp:list --><\/p>\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Estructura:<\/strong> Un tubo met\u00e1lico o de vidrio m\u00e1s corto y grueso (normalmente de 1 a 5 metros de largo y 2 a 4 mm de di\u00e1metro interior) lleno de part\u00edculas s\u00f3lidas inertes (por ejemplo, tierra de diatomeas) recubiertas de fase estacionaria.<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li><strong>Ventajas:<\/strong><!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Gran capacidad de muestras<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Preparaci\u00f3n sencilla y bajo coste<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list --><\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li><strong>Desventajas:<\/strong><!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Eficacia de separaci\u00f3n muy inferior a la de las columnas capilares<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>An\u00e1lisis m\u00e1s lento<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list --><\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li><strong>Aplicaciones:<\/strong> Utilizado principalmente para separar gases permanentes (O\u2082, N\u2082, CO\u2082) o para cromatograf\u00eda preparativa.<\/li>\n<!-- \/wp:list-item --><\/ul>\n<p><!-- \/wp:list --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41b04e2 elementor-widget elementor-widget-heading\" data-id=\"41b04e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Elegir la columna de cromatograf\u00eda de gases adecuada<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b1d00d7 elementor-widget elementor-widget-text-editor\" data-id=\"b1d00d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La selecci\u00f3n de una columna cromatogr\u00e1fica es un paso cr\u00edtico en el desarrollo de un m\u00e9todo anal\u00edtico e implica principalmente considerar los cuatro par\u00e1metros siguientes:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b2762d4 elementor-widget elementor-widget-shortcode\" data-id=\"b2762d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-7\" class=\"tablepress tablepress-id-7\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Par\u00e1metro de selecci\u00f3n<\/th><th class=\"column-2\">Descripci\u00f3n<\/th><th class=\"column-3\">Ejemplos comunes de selecci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">1. Fase estacionaria<\/td><td class=\"column-2\">\u00c9ste es el factor m\u00e1s importante. Bas\u00e1ndose en el principio \"lo semejante se disuelve con lo semejante\", elija una fase estacionaria cuya polaridad coincida con la de los analitos.<\/td><td class=\"column-3\">- Para compuestos no polares (por ejemplo, hidrocarburos): elija columnas no polares (por ejemplo, DB-5).<br \/>\n- Para compuestos polares (por ejemplo, alcoholes, aldeh\u00eddos): elija columnas polares (por ejemplo, WAX).<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">2. Longitud de columna<\/td><td class=\"column-2\">Normalmente, las columnas m\u00e1s largas proporcionan una mejor separaci\u00f3n, pero tambi\u00e9n aumentan el tiempo de an\u00e1lisis.<\/td><td class=\"column-3\">- Separaci\u00f3n general: 15-30 m.<br \/>\n- Muestras muy complejas: 50-60 m.<br \/>\n- An\u00e1lisis r\u00e1pido: 5-15 m.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">3. Di\u00e1metro interior (DI)<\/td><td class=\"column-2\">Un DI m\u00e1s peque\u00f1o proporciona una mayor eficacia de separaci\u00f3n pero una menor capacidad de muestra.<\/td><td class=\"column-3\">- An\u00e1lisis general de alta resoluci\u00f3n: 0,25 mm.<br \/>\n- Inyecci\u00f3n de gran volumen (por ejemplo, an\u00e1lisis de trazas): 0,53 mm (columnas de gran di\u00e1metro).<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">4. Espesor de la pel\u00edcula<\/td><td class=\"column-2\">\t<br \/>\nLas pel\u00edculas finas proporcionan un an\u00e1lisis m\u00e1s r\u00e1pido y son adecuadas para compuestos de alto punto de ebullici\u00f3n; las pel\u00edculas gruesas tienen mayor capacidad y mejoran la retenci\u00f3n de compuestos muy vol\u00e1tiles.<\/td><td class=\"column-3\">- An\u00e1lisis de rutina: 0,25 \u00b5m.<br \/>\n- Gases\/sustancias de bajo punto de ebullici\u00f3n: 1,0 \u00b5m o m\u00e1s grueso.<br \/>\n- Compuestos de alto punto de ebullici\u00f3n: 0,1 \u00b5m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-7 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-addc20c elementor-widget elementor-widget-text-editor\" data-id=\"addc20c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4 class=\"wp-block-heading\"><strong>Una v\u00edvida analog\u00eda<\/strong><\/h4>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Puede imaginarse una columna de cromatograf\u00eda de gases como una autopista con m\u00faltiples estaciones de peaje:<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:list --><\/p>\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Gas portador:<\/strong> como el viento que empuja los veh\u00edculos<\/li>\n<!-- \/wp:list-item --><!-- wp:list-item -->\n<li><strong>Mol\u00e9culas de muestra:<\/strong> como motos, coches y camiones<\/li>\n<!-- \/wp:list-item --><!-- wp:list-item -->\n<li><strong>Fase estacionaria:<\/strong> Como las normas de las estaciones de peaje: algunas cobran menos a las motos (interacci\u00f3n d\u00e9bil) y m\u00e1s a los coches (interacci\u00f3n fuerte).<\/li>\n<!-- \/wp:list-item --><\/ul>\n<p><!-- \/wp:list --><!-- wp:paragraph --><\/p>\n<p><strong>Proceso de separaci\u00f3n:<\/strong><br \/>Todos los veh\u00edculos arrancan al mismo tiempo. Las motos (interacci\u00f3n d\u00e9bil) pasan r\u00e1pidamente por las estaciones de peaje y llegan las primeras a su destino. Los coches (interacci\u00f3n fuerte) hacen cola en cada estaci\u00f3n y llegan los \u00faltimos.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p><strong>Cromatograma:<\/strong><br \/>El registrador muestra picos correspondientes a motocicletas, coches y camiones que llegan a distintas horas.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f78599c elementor-widget elementor-widget-heading\" data-id=\"f78599c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Resumen<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1829ba3 elementor-widget elementor-widget-text-editor\" data-id=\"1829ba3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una columna de cromatograf\u00eda de gases es un componente de precisi\u00f3n que separa sustancias bas\u00e1ndose en las diferencias de partici\u00f3n entre la fase m\u00f3vil (gas portador) y la fase estacionaria. Es el n\u00facleo de la cromatograf\u00eda de gases, y la elecci\u00f3n de la columna determina directamente el \u00e9xito del an\u00e1lisis.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3724c9b elementor-widget elementor-widget-heading\" data-id=\"3724c9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Gu\u00eda para el desarrollo de m\u00e9todos de cromatograf\u00eda de gases en columna<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9c315a elementor-widget elementor-widget-text-editor\" data-id=\"b9c315a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><!-- wp:paragraph --><\/p>\n<p>La selecci\u00f3n de una columna de cromatograf\u00eda de gases adecuada es el paso m\u00e1s cr\u00edtico en el desarrollo de un m\u00e9todo anal\u00edtico. El siguiente marco va de conceptos sencillos a avanzados para ayudarle a dominar sistem\u00e1ticamente el proceso de selecci\u00f3n.<\/p>\n<p><!-- \/wp:paragraph --> <!-- wp:heading --><\/p>\n<h4 class=\"wp-block-heading\"><strong>Principio b\u00e1sico: \"Lo semejante disuelve lo semejante\"<\/strong><\/h4>\n<p><!-- \/wp:heading --> <!-- wp:paragraph --><\/p>\n<p>\u00c9sta es la regla fundamental para seleccionar una columna de GC. La polaridad de la fase estacionaria debe coincidir con la polaridad de sus analitos objetivo.<\/p>\n<p><!-- \/wp:paragraph --> <!-- wp:list --><\/p>\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Compuestos no polares o d\u00e9bilmente polares \u2192 Elegir una fase estacionaria no polar.<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Compuestos polares \u2192 Elija una fase estacionaria polar.<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Mezclas separadas principalmente por punto de ebullici\u00f3n \u2192 Prefiera fases estacionarias no polares.<\/li>\n<!-- \/wp:list-item --><\/ul>\n<p><!-- \/wp:list --> <!-- wp:heading --><\/p>\n<h4 class=\"wp-block-heading\"><strong>Par\u00e1metros clave de selecci\u00f3n: Cuatro dimensiones<\/strong><\/h4>\n<p><!-- \/wp:heading --> <!-- wp:paragraph --><\/p>\n<p>Una columna GC capilar tiene cuatro par\u00e1metros esenciales. Juntos, determinan el rendimiento de separaci\u00f3n, la velocidad y la capacidad anal\u00edtica.<br \/>Piense en ellos como en las configuraciones de un coche:<\/p>\n<p><!-- \/wp:paragraph --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-592e27b elementor-widget elementor-widget-shortcode\" data-id=\"592e27b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-8\" class=\"tablepress tablepress-id-8\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Par\u00e1metro<\/th><th class=\"column-2\">\u00bfCon qu\u00e9 se compara en un coche?<\/th><th class=\"column-3\">\u00bfC\u00f3mo afecta a la selecci\u00f3n?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">1. Fase estacionaria<\/td><td class=\"column-2\">Tipo de motor (gasolina, el\u00e9ctrico, h\u00edbrido)<\/td><td class=\"column-3\">La elecci\u00f3n m\u00e1s importante. Determina la selectividad: qui\u00e9n eluye primero y qui\u00e9n eluye despu\u00e9s.<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">2. Di\u00e1metro interior (DI)<\/td><td class=\"column-2\">Anchura de carril<\/td><td class=\"column-3\">ID m\u00e1s peque\u00f1o = mayor eficacia (picos m\u00e1s n\u00edtidos) pero menor capacidad de la columna.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">3. Longitud de columna<\/td><td class=\"column-2\">Longitud de la v\u00eda<\/td><td class=\"column-3\">Columna m\u00e1s larga = mayor poder de resoluci\u00f3n pero mayor tiempo de an\u00e1lisis y mayor presi\u00f3n de entrada.<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">4. Espesor de la pel\u00edcula<\/td><td class=\"column-2\">Rugosidad de la calzada<\/td><td class=\"column-3\">Pel\u00edcula m\u00e1s gruesa = retenci\u00f3n m\u00e1s fuerte (buena para compuestos vol\u00e1tiles). Pel\u00edcula m\u00e1s fina = an\u00e1lisis m\u00e1s r\u00e1pido (bueno para sustancias de alto punto de ebullici\u00f3n).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-8 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47e1ae5 elementor-widget elementor-widget-heading\" data-id=\"47e1ae5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Gu\u00eda de selecci\u00f3n paso a paso<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-095eceb elementor-widget elementor-widget-heading\" data-id=\"095eceb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Paso 1: Determinar la fase estacionaria (decisi\u00f3n m\u00e1s importante)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3172563 elementor-widget elementor-widget-text-editor\" data-id=\"3172563\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Este es el n\u00facleo de la selectividad. A continuaci\u00f3n se presentan las fases estacionarias m\u00e1s comunes y sus estrategias de selecci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c597b6 elementor-widget elementor-widget-shortcode\" data-id=\"6c597b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-9\" class=\"tablepress tablepress-id-9\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Tipo de fase estacionaria<\/th><th class=\"column-2\">Polaridad<\/th><th class=\"column-3\">Ejemplos de modelos similares<\/th><th class=\"column-4\">Principales aplicaciones (qu\u00e9 analiza)<\/th><th class=\"column-5\">Caracter\u00edsticas y consejos de selecci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">100% Dimetilpolisiloxano<\/td><td class=\"column-2\">No polar<\/td><td class=\"column-3\">DB-1, HP-1, OV-1, Rtx-1<\/td><td class=\"column-4\">Hidrocarburos, aceites esenciales, pesticidas, productos petrol\u00edferos<\/td><td class=\"column-5\">Columna de uso general. La separaci\u00f3n sigue el orden del punto de ebullici\u00f3n. Los compuestos de bajo punto de ebullici\u00f3n eluyen primero. Si no est\u00e1 seguro de qu\u00e9 elegir, puede empezar con este tipo.<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">5% Fenil - 95% Dimetilpolisiloxano<\/td><td class=\"column-2\">D\u00e9bilmente polar<\/td><td class=\"column-3\">DB-5, HP-5, OV-5, Rtx-5<\/td><td class=\"column-4\">La columna de uso general m\u00e1s utilizada, adecuada para la mayor\u00eda de aplicaciones, como productos farmac\u00e9uticos, contaminantes medioambientales y fragancias.<\/td><td class=\"column-5\">Selectividad ligeramente m\u00e1s amplia en comparaci\u00f3n con las columnas de metilo 100%, capaces de separar m\u00e1s tipos de compuestos. Es la columna de primera elecci\u00f3n m\u00e1s utilizada en los laboratorios.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">50% Fenil - 50% Dimetilpolisiloxano<\/td><td class=\"column-2\">Polaridad media<\/td><td class=\"column-3\">DB-17, HP-50+, Rtx-50<\/td><td class=\"column-4\">Productos farmac\u00e9uticos, esteroides, pesticidas<\/td><td class=\"column-5\">Proporciona una mejor retenci\u00f3n y separaci\u00f3n de los compuestos arom\u00e1ticos.<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Polietilenglicol (PEG)<\/td><td class=\"column-2\">Polar<\/td><td class=\"column-3\">DB-WAX, HP-INNOWax, Stabilwax<\/td><td class=\"column-4\">Alcoholes, aldeh\u00eddos, cetonas, \u00e1cidos grasos, fragancias<\/td><td class=\"column-5\">Columna fuertemente polar. Tenga en cuenta que la temperatura m\u00e1xima de funcionamiento es relativamente baja (~250\u00b0C) y que es propensa a la degradaci\u00f3n oxidativa.<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Cianopropil-fenil-dimetilpolisiloxano<\/td><td class=\"column-2\">Polaridad media-fuerte<\/td><td class=\"column-3\">DB-624, Rtx-624, VF-1701<\/td><td class=\"column-4\">Compuestos org\u00e1nicos vol\u00e1tiles, disolventes residuales, precursores del ozono<\/td><td class=\"column-5\">Alta selectividad para compuestos polares; ampliamente utilizado en los m\u00e9todos reglamentarios de la EPA.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-9 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b76af1 elementor-widget elementor-widget-text-editor\" data-id=\"2b76af1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><!-- wp:heading {\"level\":3} --><\/p>\n<h4 class=\"wp-block-heading\"><strong>Estrategia de selecci\u00f3n<\/strong><\/h4>\n<p><!-- \/wp:heading --> <!-- wp:list --><\/p>\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Para principiantes o an\u00e1lisis general: Comience con DB-5 (o equivalente).<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Si se sigue un m\u00e9todo est\u00e1ndar: Siga los requisitos del m\u00e9todo (EPA, farmacopea, etc.).<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Para compuestos polares fuertes (alcoholes, \u00e1cidos): Elija columnas WAX.<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Para is\u00f3meros o necesidades de alta selectividad: Consulte la bibliograf\u00eda o las tablas de selecci\u00f3n de columnas del proveedor.<\/li>\n<!-- \/wp:list-item --><\/ul>\n<p><!-- \/wp:list --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-873f4c2 elementor-widget elementor-widget-heading\" data-id=\"873f4c2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Paso 2: Determinar el di\u00e1metro interior<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41c6582 elementor-widget elementor-widget-shortcode\" data-id=\"41c6582\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-10\" class=\"tablepress tablepress-id-10\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Di\u00e1metro interior<\/th><th class=\"column-2\">Caracter\u00edsticas<\/th><th class=\"column-3\">Escenarios aplicables<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">0,53 mm<\/td><td class=\"column-2\">Gran calibre; mayor capacidad; menor eficiencia<\/td><td class=\"column-3\">Muestras de alta concentraci\u00f3n, an\u00e1lisis de gases, detectores TCD, inyecci\u00f3n directa<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">0,32 mm<\/td><td class=\"column-2\">Buen equilibrio entre capacidad y eficiencia<\/td><td class=\"column-3\">An\u00e1lisis rutinarios que requieren mayor capacidad<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">0,25 mm<\/td><td class=\"column-2\">El m\u00e1s utilizado; alta eficiencia<\/td><td class=\"column-3\">An\u00e1lisis general y mezclas complejas<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">0,18 \/ 0,15 mm<\/td><td class=\"column-2\">Mayor eficiencia; m\u00e1s r\u00e1pido; capacidad m\u00ednima<\/td><td class=\"column-3\">GC r\u00e1pida, GC-MS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-10 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d969e21 elementor-widget elementor-widget-text-editor\" data-id=\"d969e21\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Consejo de selecci\u00f3n:<br \/>A menos que se requiera lo contrario, comience con 0,25 mm o 0,32 mm.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed4ad7e elementor-widget elementor-widget-heading\" data-id=\"ed4ad7e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Paso 3: Determinar la longitud de la columna<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-23316f2 elementor-widget elementor-widget-shortcode\" data-id=\"23316f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-11\" class=\"tablepress tablepress-id-11\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Longitud de columna<\/th><th class=\"column-2\">Caracter\u00edsticas<\/th><th class=\"column-3\">Escenarios aplicables<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">5-15 m<\/td><td class=\"column-2\">An\u00e1lisis r\u00e1pido; baja presi\u00f3n de entrada; poder de resoluci\u00f3n limitado<\/td><td class=\"column-3\">Muestras sencillas, GC r\u00e1pida, cribado<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">30 m<\/td><td class=\"column-2\">El mejor equilibrio entre resoluci\u00f3n y tiempo<\/td><td class=\"column-3\">Elecci\u00f3n por defecto para la mayor\u00eda de las aplicaciones<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">50-60 m<\/td><td class=\"column-2\">M\u00e1ximo poder de resoluci\u00f3n; largo tiempo de funcionamiento; alta presi\u00f3n de entrada<\/td><td class=\"column-3\">Muestras extremadamente complejas (como petr\u00f3leo y aceites esenciales), cuando se requiere la m\u00e1xima resoluci\u00f3n.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-11 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-705f753 elementor-widget elementor-widget-text-editor\" data-id=\"705f753\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Consejo de selecci\u00f3n:<br \/>Utilice 30 m por defecto. Aumente a 50-60 m solo si la resoluci\u00f3n es insuficiente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78e3366 elementor-widget elementor-widget-heading\" data-id=\"78e3366\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Paso 4: Determinar el espesor de la pel\u00edcula<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-21b67a0 elementor-widget elementor-widget-shortcode\" data-id=\"21b67a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-12\" class=\"tablepress tablepress-id-12\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Espesor de la pel\u00edcula<\/th><th class=\"column-2\">Caracter\u00edsticas<\/th><th class=\"column-3\">Escenarios aplicables<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">0,10-0,25 \u00b5m<\/td><td class=\"column-2\">Pel\u00edcula fina; retenci\u00f3n d\u00e9bil; eluci\u00f3n r\u00e1pida; sangrado bajo<\/td><td class=\"column-3\">Compuestos de alto punto de ebullici\u00f3n, analitos sensibles al calor, an\u00e1lisis r\u00e1pidos<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">0,25-0,50 \u00b5m<\/td><td class=\"column-2\">Est\u00e1ndar y m\u00e1s utilizado<\/td><td class=\"column-3\">Por defecto para la mayor\u00eda de las aplicaciones<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">1,0-5,0 \u00b5m<\/td><td class=\"column-2\">Pel\u00edcula gruesa; fuerte retenci\u00f3n; alta capacidad<\/td><td class=\"column-3\">Compuestos de bajo punto de ebullici\u00f3n y muy vol\u00e1tiles (gases, disolventes)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-12 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1eafd0 elementor-widget elementor-widget-text-editor\" data-id=\"e1eafd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Consejo de selecci\u00f3n:<br \/>Por defecto = 0,25 \u00b5m.<br \/>Para gases\/solventes ligeros \u2192 1,0 \u00b5m o m\u00e1s grueso.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-081a5a1 elementor-widget elementor-widget-heading\" data-id=\"081a5a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Diagrama de selecci\u00f3n r\u00e1pida (resumen)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b532e2 elementor-widget elementor-widget-text-editor\" data-id=\"1b532e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><!-- wp:list {\"ordered\":true} --><\/p>\n<ol class=\"wp-block-list\"><!-- wp:list-item -->\n<li>\u00bfExiste un m\u00e9todo est\u00e1ndar?<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>S\u00ed \u2192 Siga exactamente las especificaciones.<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>No \u2192 Continuar.<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list --><\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>\u00bfCu\u00e1les son los compuestos objetivo?<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Polaridad desconocida o mixta \u2192 Empezar con equivalente DB-5.<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Fuertemente polar (alcoholes, \u00e1cidos) \u2192 Elija CERA.<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Otros \u2192 Consultar bibliograf\u00eda u orientaci\u00f3n del proveedor<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list --><\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>\"Configuraci\u00f3n universal\" recomendada:<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Fase estacionaria: 5% fenil-95% dimetilpolisiloxano (por ejemplo, DB-5)<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Di\u00e1metro interior: 0,25 mm o 0,32 mm<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Longitud: 30 m<\/li>\n<!-- \/wp:list-item --> <!-- wp:list-item -->\n<li>Espesor de la pel\u00edcula: 0,25 \u00b5m<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list --><\/li>\n<!-- \/wp:list-item --><\/ol>\n<p><!-- \/wp:list --> <!-- wp:paragraph --><\/p>\n<p>Esta \"configuraci\u00f3n universal\"<br \/>(por ejemplo, DB-5, 30 m \u00d7 0,25 mm \u00d7 0,25 \u00b5m)<br \/>resuelve m\u00e1s del 80% de los problemas anal\u00edticos rutinarios de GC.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bcc5b13 elementor-widget elementor-widget-text-editor\" data-id=\"bcc5b13\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Espero que esta gu\u00eda detallada le ayude a tomar decisiones seguras y bien informadas durante el desarrollo del m\u00e9todo GC.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2fa790d elementor-widget elementor-widget-heading\" data-id=\"2fa790d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">C\u00f3mo elegir una columna capilar de cromatograf\u00eda de gases adecuada<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80ab58f elementor-widget elementor-widget-text-editor\" data-id=\"80ab58f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Las columnas capilares de cromatograf\u00eda de gases son el componente central responsable de la separaci\u00f3n; son el coraz\u00f3n del sistema de cromatograf\u00eda de gases. Para elegir una columna capilar comercial adecuada, los principales factores a tener en cuenta son la fase estacionaria, el di\u00e1metro interno, la longitud de la columna y el grosor de la pel\u00edcula. En las secciones siguientes se analiza cada factor en detalle.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4aff879 elementor-widget elementor-widget-heading\" data-id=\"4aff879\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">I. Selecci\u00f3n de la fase estacionaria<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5028f31 elementor-widget elementor-widget-text-editor\" data-id=\"5028f31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Te\u00f3ricamente, la fase estacionaria de una columna capilar se selecciona seg\u00fan el principio de similitud:<br \/>utilizar una fase estacionaria no polar para analitos no polares, una fase estacionaria polar para analitos polares y una fase estacionaria que contenga grupos arom\u00e1ticos para analitos arom\u00e1ticos.<\/p>\n<p>\u2460 Para un analito desconocido, puede aplicarse un m\u00e9todo de ensayo y error: empezar con una columna no polar o d\u00e9bilmente polar, como SPB-1 o SPB-5. Si el resultado no es satisfactorio, pruebe gradualmente con columnas de polaridad creciente, de media polaridad a muy polar, hasta conseguir un resultado anal\u00edtico aceptable que determine la polaridad adecuada.<\/p>\n<p>\u2461 Las columnas capilares de baja sangr\u00eda (\"ms\") son generalmente m\u00e1s inertes y tienen l\u00edmites superiores de temperatura m\u00e1s altos, adecuados para detectores de EM.<\/p>\n<p>\u2462 Cuando pueda utilizarse una fase estacionaria no polar, evite elegir una polar; las fases estacionarias no polares suelen tener tiempos de vida m\u00e1s largos.<\/p>\n<p>\u2463 Elegir una fase estacionaria con polaridad similar a la del analito.<\/p>\n<p>Las columnas \u2464 PLOT se utilizan para analizar muestras gaseosas a temperaturas de columna superiores a la temperatura ambiente.<\/p>\n<p>\u2465 Para separar is\u00f3meros de hidrocarburos arom\u00e1ticos como los xilenos, se prefieren las columnas capilares altamente polares de tipo cera.<\/p>\n<p>\u2466 Al validar un m\u00e9todo anal\u00edtico, pueden utilizarse simult\u00e1neamente columnas no polares y polares para confirmar la identificaci\u00f3n de picos o los resultados de separaci\u00f3n.<\/p>\n<p>\u2467 Para la validaci\u00f3n de m\u00e9todos de an\u00e1lisis de plaguicidas, se prefieren columnas capilares de polaridad d\u00e9bil a moderada (como el polisiloxano 5% fenil\/95% fenil-metil, o el polisiloxano 7% cianopropil\/7% fenil\/86% metil).<br \/>Para la validaci\u00f3n del m\u00e9todo de an\u00e1lisis del disolvente residual, se utilizan columnas moderada o d\u00e9bilmente polares (como -5MS o -624\/-VMS).<br \/>Para la validaci\u00f3n de los an\u00e1lisis de alcohol o FAME, se utilizan fases estacionarias que contienen PEG o cianopropilo.<br \/>Para analizar los oxigenados en la gasolina, se recomiendan las columnas capilares -1 y PEG.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b36beab elementor-widget elementor-widget-image\" data-id=\"b36beab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"294\" height=\"269\" src=\"https:\/\/quartz.10smt.com\/wp-content\/uploads\/2025\/11\/Gas-Chromatography-Capillary-Column.jpg\" class=\"attachment-large size-large wp-image-1333\" alt=\"Columna capilar de cromatograf\u00eda de gases\" srcset=\"https:\/\/quartz.10smt.com\/wp-content\/uploads\/2025\/11\/Gas-Chromatography-Capillary-Column.jpg 294w, https:\/\/quartz.10smt.com\/wp-content\/uploads\/2025\/11\/Gas-Chromatography-Capillary-Column-13x12.jpg 13w\" sizes=\"(max-width: 294px) 100vw, 294px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Columna capilar de cromatograf\u00eda de gases<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-adf5b00 elementor-widget elementor-widget-heading\" data-id=\"adf5b00\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">II. Di\u00e1metro interno de las columnas capilares<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa14fa3 elementor-widget elementor-widget-text-editor\" data-id=\"aa14fa3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El di\u00e1metro interno afecta al n\u00famero te\u00f3rico de placas, la resoluci\u00f3n, el tiempo de retenci\u00f3n, la presi\u00f3n de entrada, el caudal de gas portador y la capacidad de la muestra.<\/p>\n<p>\u2460 Para una alta eficacia de la columna, utilice columnas capilares de 0,18-0,25 mm de di\u00e1metro interior, que ofrecen n\u00fameros de platos te\u00f3ricos elevados. La columna de 0,18 mm es adecuada para sistemas GC\/MS con baja capacidad de bombeo. Las columnas de di\u00e1metro peque\u00f1o tienen la menor capacidad y requieren la mayor presi\u00f3n de entrada.<\/p>\n<p>\u2461 Para una mayor capacidad de muestra, utilice una columna de D.I. de 0,32 mm. En comparaci\u00f3n con las columnas de D.I. de 0,25 mm, las columnas de D.I. de 0,32 mm suelen ofrecer una mejor separaci\u00f3n de los picos de eluci\u00f3n temprana durante las inyecciones sin divisi\u00f3n o de gran volumen (&gt;2 \u00b5l).<\/p>\n<p>\u2462 S\u00f3lo debe utilizarse una columna de 0,45 mm de di\u00e1metro interior cuando el instrumento est\u00e9 equipado con un inyector directo de gran calibre y cuando se necesite una alta eficacia de columna. Es ideal para aplicaciones de alto flujo portador, como purga y trampa, muestreo de espacio de cabeza e inyecci\u00f3n en v\u00e1lvula.<\/p>\n<p>\u2463 Una columna de 0,53 mm de di\u00e1metro interior s\u00f3lo debe utilizarse con un puerto de inyecci\u00f3n directa de gran calibre. Tambi\u00e9n es adecuada para aplicaciones de alto flujo portador, como el muestreo de purga y trampa y de espacio de cabeza. Con el mismo grosor de pel\u00edcula, las columnas de 0,53 mm tienen la mayor capacidad de muestra. Muchos laboratorios farmac\u00e9uticos suelen utilizar este tama\u00f1o.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d2517f elementor-widget elementor-widget-heading\" data-id=\"5d2517f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">III. Longitud de la columna<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ddd56b7 elementor-widget elementor-widget-text-editor\" data-id=\"ddd56b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La longitud de la columna afecta a su eficacia, resoluci\u00f3n, tiempo de retenci\u00f3n y presi\u00f3n del gas portador.<\/p>\n<p>\u2460 Las columnas de 10-15 m son adecuadas para muestras que contienen solutos f\u00e1ciles de separar o pocos solutos. Las columnas de di\u00e1metro peque\u00f1o suelen ser m\u00e1s cortas para reducir la presi\u00f3n de entrada.<\/p>\n<p>\u2461 Una columna de 15 m se utiliza para analitos sencillos. Una columna de 30 m se utiliza habitualmente para analizar mezclas que contienen entre 10 y 50 componentes. Si se desconoce la longitud \u00f3ptima, comience con una columna de 25-30 m.<\/p>\n<p>\u2462 Cuando no se pueda conseguir una resoluci\u00f3n satisfactoria mediante otros ajustes (menor di\u00e1metro interno, fase estacionaria diferente o cambios de temperatura), utilice una columna de 50-60 m. Estas son adecuadas para muestras complejas con muchos solutos. Sin embargo, aumentan el tiempo de an\u00e1lisis y el coste.<\/p>\n<p>\u2463 La longitud de la columna no es un par\u00e1metro absolutamente cr\u00edtico. Aumentar la longitud mejora la eficiencia y la resoluci\u00f3n, pero tambi\u00e9n aumenta el tiempo de an\u00e1lisis. Las columnas m\u00e1s cortas reducen el coste del an\u00e1lisis y, al reducir la cantidad de material de la columna, disminuyen las posibles interacciones con los sitios activos, lo que reduce la formaci\u00f3n de colas en los picos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba2d0cd elementor-widget elementor-widget-heading\" data-id=\"ba2d0cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">IV. Espesor de la pel\u00edcula<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47b6eb8 elementor-widget elementor-widget-text-editor\" data-id=\"47b6eb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El grosor de la pel\u00edcula afecta principalmente a las caracter\u00edsticas de retenci\u00f3n, resoluci\u00f3n, sangrado, inercia y capacidad de la muestra.<\/p>\n<p>\u2460 Para columnas de 0,18-0,32 mm de di\u00e1metro interior, el espesor medio o est\u00e1ndar de la pel\u00edcula es de 0,18-0,25 \u03bcm, adecuado para la mayor\u00eda de los an\u00e1lisis.<br \/>Para columnas de 0,45-0,53 mm de di\u00e1metro interior, el grosor t\u00edpico de la pel\u00edcula es de 0,8-1,5 \u03bcm.<\/p>\n<p>\u2461 Para analitos de baja volatilidad, alto punto de ebullici\u00f3n o termosensibles, elija un grosor de pel\u00edcula de 0,25-0,5 \u03bcm, principalmente para analitos con puntos de ebullici\u00f3n inferiores a 300\u00b0C. Para analitos con puntos de ebullici\u00f3n superiores a 300 \u00b0C, utilice pel\u00edculas m\u00e1s finas (0,1 \u03bcm) combinadas con columnas m\u00e1s cortas.<\/p>\n<p>\u2462 Para aplicaciones GC-MS, se suele seleccionar un grosor de pel\u00edcula de 0,1-0,2 \u03bcm. Las pel\u00edculas de grosor medio (1-1,5 \u03bcm) se utilizan principalmente para analitos que hierven entre 100 y 200 \u00b0C.<\/p>\n<p>\u2463 Para analitos de bajo punto de ebullici\u00f3n, como el acetaldeh\u00eddo, deben utilizarse pel\u00edculas m\u00e1s gruesas (3-5 \u03bcm) para permitir el an\u00e1lisis a temperaturas m\u00e1s elevadas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4e38bf elementor-widget elementor-widget-heading\" data-id=\"f4e38bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">V. Conclusi\u00f3n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dbc3a65 elementor-widget elementor-widget-text-editor\" data-id=\"dbc3a65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Las distintas columnas capilares muestran comportamientos de retenci\u00f3n muy diferentes. La elecci\u00f3n de la columna capilar adecuada es esencial para el \u00e9xito del an\u00e1lisis cromatogr\u00e1fico de gases. La selecci\u00f3n debe seguir las propiedades de los analitos, los principios te\u00f3ricos de selecci\u00f3n de columnas y las recomendaciones de uso del fabricante.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fec9fff e-con-full e-flex e-con e-child\" data-id=\"fec9fff\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-971d6cd elementor-widget elementor-widget-heading\" data-id=\"971d6cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Solicitar soluci\u00f3n de vidrio de cuarzo<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5b1627 elementor-widget elementor-widget-text-editor\" data-id=\"a5b1627\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fabricamos tubos de cuarzo utilizados en cromatograf\u00eda de gases y sistemas anal\u00edticos relacionados.<\/p>\n<p>Si est\u00e1 seleccionando materiales para columnas, evaluando dimensiones o necesita soluciones personalizadas para tubos de cuarzo, puede ponerse en contacto con nosotros para un debate t\u00e9cnico o para recibir un presupuesto.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d292efd elementor-widget elementor-widget-form\" data-id=\"d292efd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"form.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Gas Chromatography Columns (Definition \u00b7 Selection \u00b7 Method Development) This article focuses on gas chromatography columns, starting from the most [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1333,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_seopress_titles_title":"Gas Chromatography Columns: Principles, Types, and Selection","_seopress_titles_desc":"Gas chromatography columns explained, including working principles, column types, fixed phases, and key parameters for selecting columns in GC method development.","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":"gas chromatography column","site-sidebar-layout":"no-sidebar","site-content-layout":"","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2180","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/quartz.10smt.com\/es\/wp-json\/wp\/v2\/pages\/2180","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/quartz.10smt.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/quartz.10smt.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/quartz.10smt.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/quartz.10smt.com\/es\/wp-json\/wp\/v2\/comments?post=2180"}],"version-history":[{"count":238,"href":"https:\/\/quartz.10smt.com\/es\/wp-json\/wp\/v2\/pages\/2180\/revisions"}],"predecessor-version":[{"id":3697,"href":"https:\/\/quartz.10smt.com\/es\/wp-json\/wp\/v2\/pages\/2180\/revisions\/3697"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/quartz.10smt.com\/es\/wp-json\/wp\/v2\/media\/1333"}],"wp:attachment":[{"href":"https:\/\/quartz.10smt.com\/es\/wp-json\/wp\/v2\/media?parent=2180"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}